1.
Indian J Clin Biochem ; 38(3): 324-330, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37234184

RESUMEN

Peru is one of the countries with the highest lead contamination in the world. Biological monitoring has limitations due to the shortage of laboratories with validated methodologies for the measurement of blood lead, and it is necessary to use alternative methods for its measurement in high-altitude cities. We aimed to compare the blood lead levels (BLL) measured by the LeadCare II (LC) method and Graphite Furnace Atomic Absorption Spectrometry (GF-AAS). We measured the BLL of 108 children from the city of La Oroya. The mean and median BLL for GF-AAS were 10.77 ± 4.18 and 10.44 µg/dL, respectively; for the LC method, the mean was 11.71 ± 4.28 and the median was 11.60 µg/dL. We found a positive linear correlation (Rho = 0.923) between both methods. Notwithstanding, the Wilcoxon test suggests a significant difference between both methods (ρ = 0.000). In addition, the Bland-Altman analysis indicates that there is a positive bias (0.94) in the LC method, and this method tends to overestimate the BLL. Likewise, we performed a generalized linear model to evaluate the influence of age and hemoglobin on BLL. We found that age and hemoglobin had a significant influence on BLL measured by the LC method. Finally, we used two non-parametric linear regression methods (Deming and Passing-Bablok regression) to compare the LC method with the GF-AAS. We found that these methods differ by at least a constant amount, and there would be a proportional difference between both. Although in general there is a positive linear correlation, the results of both methods differ significantly. Therefore, its use in cities located at high altitudes (higher than 2440 m.a.s.l.) would not be recommended.

2.
Rev Peru Med Exp Salud Publica ; 38(3): 391-398, 2021.
Artículo en Español, Inglés | MEDLINE | ID: mdl-34932740

RESUMEN

OBJECTIVE: To develop a methodology for evaluating the level of respiratory protection provided by respirators, surgical masks and community face masks used by the Peruvian population; protection was evaluated against particles of a size similar to those containing active SARS-CoV-2 virus. MATERIALS AND METHODS: A direct linear relationship has been determined between the logarithm of the concentration of airborne particles and the elapsed time; thus, it is possible to compare the quantity of particles inside and outside of the mask or respirator in the same time period, as well as to obtain the percentage of respiratory protection for each evaluated sample. RESULTS: A methodology was established to evaluate the level of respiratory protection against aerosols smaller than 5.0 µm. Also, the use of accessories such as rubber bands or adjusters behind the head and neck, and the use of robust nasal clips, significantly increased the level of respiratory protection against particles with a high probability of containing SARS-CoV-2. CONCLUSIONS: We found concordance between the obtained respiratory protection values and those expected, considering the filtration level of the material used for each surgical mask or respirator, as well as the tightness. A significant increase in the levels of respiratory protection was observed.


OBJETIVO: Desarrollar una metodología para evaluar el nivel de protección respiratoria de respiradores, mascarillas quirúrgicas y mascarillas comunitarias que usa la población peruana, usando partículas de un tamaño similar a las que contienen al virus activo del SARS-CoV-2. MATERIALES Y MÉTODOS: Se ha determinado una relación lineal directa entre el logaritmo de la concentración de partículas suspendidas en aire y el tiempo transcurrido; por lo cual es posible comparar la cantidad de partículas internas y externas a la mascarilla o respirador en un mismo periodo y conocer el porcentaje de protección respiratoria de cada muestra evaluada. RESULTADOS: Se ha logrado implementar una metodología para evaluar el nivel de protección respiratoria ante aerosoles menores a 5,0 µm. Asimismo, el empleo de accesorios como ligas o ajustadores detrás de cabeza y nuca, y el uso de clips nasales robustos, incrementan significativamente el nivel de protección respiratoria ante partículas con alta probabilidad de contener al SARS-CoV-2. CONCLUSIONES: Se observa una concordancia entre los valores de protección respiratoria obtenidos y los esperados, considerando el nivel de filtración del material empleado de cada mascarilla quirúrgica o respirador, y su nivel de ajuste. Se observó un incremento significativo en los niveles de protección respiratoria.


Asunto(s)
COVID-19 , Máscaras , Aerosoles , Humanos , SARS-CoV-2 , Ventiladores Mecánicos
4.
Rev. peru. med. exp. salud publica ; 38(3): 391-398, jul.-sep. 2021. tab, graf
Artículo en Español | LILACS | ID: biblio-1357384

RESUMEN

RESUMEN Objetivo: Desarrollar una metodología para evaluar el nivel de protección respiratoria de respiradores, mascarillas quirúrgicas y mascarillas comunitarias que usa la población peruana, usando partículas de un tamaño similar a las que contienen al virus activo del SARS-CoV-2. Materiales y métodos: Se ha determinado una relación lineal directa entre el logaritmo de la concentración de partículas suspendidas en aire y el tiempo transcurrido; por lo cual es posible comparar la cantidad de partículas internas y externas a la mascarilla o respirador en un mismo periodo y conocer el porcentaje de protección respiratoria de cada muestra evaluada. Resultados: Se ha logrado implementar una metodología para evaluar el nivel de protección respiratoria ante aerosoles menores a 5,0 µm. Asimismo, el empleo de accesorios como ligas o ajustadores detrás de cabeza y nuca, y el uso de clips nasales robustos, incrementan significativamente el nivel de protección respiratoria ante partículas con alta probabilidad de contener al SARS-CoV-2. Conclusiones: Se observa una concordancia entre los valores de protección respiratoria obtenidos y los esperados, considerando el nivel de filtración del material empleado de cada mascarilla quirúrgica o respirador, y su nivel de ajuste. Se observó un incremento significativo en los niveles de protección respiratoria.


ABSTRACT Objective: To develop a methodology for evaluating the level of respiratory protection provided by respirators, surgical masks and community face masks used by the Peruvian population; protection was evaluated against particles of a size similar to those containing active SARS-CoV-2 virus. Materials and methods: A direct linear relationship has been determined between the logarithm of the concentration of airborne particles and the elapsed time; thus, it is possible to compare the quantity of particles inside and outside of the mask or respirator in the same time period, as well as to obtain the percentage of respiratory protection for each evaluated sample. Results: A methodology was established to evaluate the level of respiratory protection against aerosols smaller than 5.0 μm. Also, the use of accessories such as rubber bands or adjusters behind the head and neck, and the use of robust nasal clips, significantly increased the level of respiratory protection against particles with a high probability of containing SARS-CoV-2. Conclusions: We found concordance between the obtained respiratory protection values and those expected, considering the filtration level of the material used for each surgical mask or respirator, as well as the tightness. A significant increase in the levels of respiratory protection was observed.


Asunto(s)
Dispositivos de Protección Respiratoria , Transmisión de Enfermedad Infecciosa , SARS-CoV-2 , COVID-19 , Máscaras , Ventiladores Mecánicos , Aerosoles , Valores Limites del Umbral , Pandemias , Filtración
6.
Rev. peru. med. exp. salud publica ; 35(4): 652-656, oct.-dic. 2018. tab, graf
Artículo en Español | LILACS | ID: biblio-985785

RESUMEN

RESUMEN El objetivo del estudio fue evaluar filtros domiciliarios para remover arsénico presente en agua proveniente del río Sama. El sistema estuvo compuesto de un filtro tradicional de arena y un filtro con el material adsorbente de hierro cerovalente estabilizado en quitosano. La evaluación del sistema fue por un período de 12 semanas en 18 puntos de uso; las primeras ocho semanas se determinó la concentración de arsénico del agua filtrada empleando tiras reactivas, y las cuatro últimas fueron a través de espectrometría de absorción atómica (EAA-FIAS). Durante las primeras ocho semanas se redujo la concentración de arsénico en el rango de 0,005 y 0,025 mg/L, y durante las cuatro últimas en el rango de 0,001 y 0,052 mg/L, a partir de una concentración promedio de 0,51 mg/L. Se demostró que el sistema de filtración es eficiente para remover arsénico a condiciones naturales.


ABSTRACT The objective of the study was to evaluate home filters to remove arsenic present in waters coming from the Sama river. The system consisted of a traditional sand filter and a filter with the adsorbent zerovalent iron material stabilized in quitosan. The evaluation of the system lasted for a period of 12 weeks in 18 points of usage; the first eight weeks the arsenic concentration of the filtered water was determined using reactive strips, and the last four assessment was made through atomic absorption spectrometry (AAS). During the first eight weeks the arsenic concentration was reduced in a range of 0.005 and 0.025 mg/L, and during the last four weeks in the range of 0.001 and 0.052 mg/L, from an average concentration of 0.51 mg/L. This research showed that the filtration system is efficient to remove arsenic to natural conditions


Asunto(s)
Arsénico/análisis , Contaminantes Químicos del Agua/análisis , Agua Potable/química , Ríos/química , Filtración , Salud Rural , Diseño de Equipo , Filtración/instrumentación
7.
Rev Peru Med Exp Salud Publica ; 35(4): 652-656, 2018.
Artículo en Español | MEDLINE | ID: mdl-30726432

RESUMEN

The objective of the study was to evaluate home filters to remove arsenic present in waters coming from the Sama river. The system consisted of a traditional sand filter and a filter with the adsorbent zerovalent iron material stabilized in quitosan. The evaluation of the system lasted for a period of 12 weeks in 18 points of usage; the first eight weeks the arsenic concentration of the filtered water was determined using reactive strips, and the last four assessment was made through atomic absorption spectrometry (AAS). During the first eight weeks the arsenic concentration was reduced in a range of 0.005 and 0.025 mg/L, and during the last four weeks in the range of 0.001 and 0.052 mg/L, from an average concentration of 0.51 mg/L. This research showed that the filtration system is efficient to remove arsenic to natural conditions.


El objetivo del estudio fue evaluar filtros domiciliarios para remover arsénico presente en agua proveniente del río Sama. El sistema estuvo compuesto de un filtro tradicional de arena y un filtro con el material adsorbente de hierro cerovalente estabilizado en quitosano. La evaluación del sistema fue por un período de 12 semanas en 18 puntos de uso; las primeras ocho semanas se determinó la concentración de arsénico del agua filtrada empleando tiras reactivas, y las cuatro últimas fueron a través de espectrometría de absorción atómica (EAA-FIAS). Durante las primeras ocho semanas se redujo la concentración de arsénico en el rango de 0,005 y 0,025 mg/L, y durante las cuatro últimas en el rango de 0,001 y 0,052 mg/L, a partir de una concentración promedio de 0,51 mg/L. Se demostró que el sistema de filtración es eficiente para remover arsénico a condiciones naturales.


Asunto(s)
Arsénico/análisis , Agua Potable/química , Filtración , Ríos/química , Contaminantes Químicos del Agua/análisis , Diseño de Equipo , Filtración/instrumentación , Salud Rural
SELECCIÓN DE REFERENCIAS